AGILENT U2761A DRIVER DOWNLOAD

In FM, the frequency of the carrier is varied by the instantaneous voltage of the modulating waveform. The default FSK rate value is 10 Hz. Soft Front Panel Operation On the Mod Frequency panel as shown in the desired modulating frequency value and select the unit from the drop down list. The default unit is Vpp. A Pass – Normal operation, no effect. Page Features and Functions 1 Select the Arbitrary waveform function. To output the PM waveform, configure the settings for the carrier frequency, output amplitude, offset voltage, modulating frequency, phase deviation, and the desired waveform.

Uploader: Faura
Date Added: 1 September 2018
File Size: 49.17 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 45199
Price: Free* [*Free Regsitration Required]

The following message box will appear indicating the download in progress.

Esg-a, esg-ap, esg-d, esg-dp series of rf signal generators 28 pages. Features and Functions Output Termination This configuration applies to output amplitude and offset voltage only. To disable this dialog, select the Never show this dialog option in the Show this dialog panel and click 9 For modules other than the UA Series, UA Series, UA Series, and UA, the system will perform a firmware version check on your connected Page Features and Functions 8 Saving the waveform.

Or visit Agilent worldwide web at: The table below shows the general environmental requirements for this instrument. Getting Started If you do not wish to receive similar warning messages in the future, N O T E follow the instructions below. Pulse width Rise time Period Figure Pulse waveform The range of the pulse period is from ns to s.

  HP P2-1334 NETWORK DRIVER DOWNLOAD

Agilent U2761A USB Modular Function/ Arbitrary Waveform Generator

Table of Contents Add to my manuals Add. Duty Cycle square Waves Features and Functions Duty Cycle Square Waves The duty cycle of a Square wave represents the amount of time per cycle that the Square wave is at a high level assuming that the waveform is agilenf inverted.

Click to begin the freehand draw mode or enable line draw mode. Enter text from picture: The default carrier frequency is 1 kHz for all functions. To output the PSK waveform, configure the settings for the carrier frequency, output amplitude, offset voltage, deviation, and PSK rate. Features and Functions Function Limitation If you change to a function where the maximum frequency is less than the current function, the frequency will be adjusted to the maximum value for the new function.

For more information on how to use the Measurement Manager, refer to the Agilent Measurement Manager help file. Arbitrary Waveforms Arbitrary waveform using the soft front panel. An example of the AM waveform is shown in Figure 2- Features and Functions Soft Front Panel Operation On the Offset panel as shown in desired offset value and select the unit from the drop down list. Features and Functions 8 Saving the waveform.

Remote Interface Operation FM: For a logarithmic sweep, the UA varies the output frequency in a logarithmic fashion. The default waveform is Sine wave.

  EPSON S425W DRIVER

To enable or disable the grid reference, click. Product Regulations Safety Additional Information: The following figure shows an example of a PM waveform.

Agilent UA USB Modular Function/ Arbitrary Waveform Generator | eBay

The Driver Signing Options dialog box will appear. The default modulating waveform frequency is Hz.

In This Guideā€¦ Getting Started In this chapter, you prepare your system for installation and configuration to get started with the UA. For example, if you are currently outputting a 20 MHz sine wave and then change qgilent the Ramp function, the UA will automatically adjusts the agildnt frequency to kHz the upper limit for Ramp.

For a linear sweep, the UA varies the output frequency in a linear fashion during the sweep.

Agilent UA Instrument Driver – MATLAB & Simulink

In this mode, the UA outputs continuously when the sweep mode is selected. To output the AM waveform, configure the settings for the carrier frequency, modulating frequency, depth, output amplitude, offset voltage, and the desired waveform.

To print the manual completely, please, download it.